Summary of Contents of user manual for APC Smart-UPS RT 8000VA 230V SURT8000XLI • User Manual English APC Smart-UPS® RT 8000/10000 VA 200-240 VAC Tower/Rack-Mount 6U Uninterruptible Power Supply 990-2689C 04/2006 • • Introduction The APC Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment from utility. • Hardwiring Wiring must be performed by a qualified electrician. Engineering Physics By Avadhanulu And Kshirsagar Pdf Archive.com more.

Apc Ups Troubleshooting Guide

APC Smart Ups SURT8000XLI. APC by Schneider Electric shall have no responsibility for the accuracy, correctness or objectionable nature of any user-submitted. SURT8000XLI - APC Smart-UPS RT 8000VA 230V. Service Manual, Smart UPS signalling RS-232 cable. Declaration of Conformity for Uninterruptible Power Supply. APC Smart-UPS 6000VA RT 230V Online UPS. UK Tel UK Mob. Riello UPS, APC UPS, Vertiv UPS & Eaton Powerware UPS Systems. Need Further Information? Apc Smart-UPS RT 8000VA 230V (SURT8000XLI) Smart-UPS RT 8000VA 230V. Service Manual, Smart UPS signalling RS-232 cable, User Manual, Web/SNMP Management Card.

Install a utility circuit breaker in accordance with local electrical. XLI model only: For three-phase input, set the Input Phase Selector switch (see C) to ‘3’. For single-phase input.

• Installing and Connecting the Batteries and Attaching the Front Bezel n o p q r s 4 • CONNECTING POWER AND EQUIPMENT TO THE UPS 1. Hardwire the UPS (see Hardwiring). Connect equipment to the UPS (cables. • BASIC CONNECTORS Power management software and interface kits can be used with the UPS. Serial Port Use only interface kits.

• OPERATION FRONT DISPLAY PANEL Indicator Description Online The UPS is drawing utility power and performing double conversion to supply power. • Feature Function Normal /Bypass Manually switch connected equipment to bypass mode, so that utility power is sent directly to connected. • USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD, OPTIONAL SMART SLOT ACCESSORY CARDS OR. • NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD, OPTIONAL SMART SLOT ACCESSORY CARDS OR TERMINAL MODE. • EPO (Emergency Power Off) Option The output power can be disabled in an emergency by closing a switch connected to. • Terminal Mode to Configure UPS Parameters Terminal Mode is a menu driven interface that enables enhanced configuration of the UPS. • MAINTENANCE, SERVICE, WARRANTY, AND TRANSPORTING Replacing the Battery Module(s) This UPS has easy to replace, hot-swappable battery modules.

Replacement is. • TROUBLESHOOTING Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com for. • PROBLEM AND POSSIBLE SOLUTION CAUSE BYPASS LED ILLUMINATES The bypass switch has been If bypass is the chosen mode.

• Service If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems.

• REGULATORY INFORMATION Regulatory Agency Approvals and Radio Frequency Warnings 200, 208, 220, 230, 240 V MODELS This equipment has been. • Declaration of Conformity 18 • APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in.

5/23/2016 1:05 PM Hi, I've got a SURT8000XLI with 3 additional battery bays, I have set the external battery value to 2 with only 1 external battery bay connected. I keep getting the following error and my ups battery charge is at 100% with 23% load. Discharged Battery The battery power is too low to support the load; if power fails, the UPS will be shut down immediately. When I try and perform a calibration from the web interface with 23% load and 100% battery, the ups drops everything connected to the ups, as a result, devices power cycle meaning the load goes to 0% then goes back to 23%; then battery charge shows 1% and then begins climbing back to 100%. The ups has batteries that are about 6 months old, some of which are brand new.